Rated Power 1000kWe Perkins Diesel Generator Set Base Type Oil Tank Land Power Station
1. Reliable power quality: The diesel generator set produced by our company uses the world-renowned brand Perkins engine (Perkins). Brief introduction of Perkins engine: The British Perkins Engine Company was formally established in 1932. After more than 90 years of accumulation, Perkins is the world's leading manufacturer of power equipment, with a power range of 5~2800 horsepower, widely used in construction machinery and mining machinery , agricultural machinery, ships, oil and gas fields.
2. Reliable generator quality: The diesel generators produced by our company are equipped with generators with reliable quality and high market holdings, such as ① Stamford generator (STAMFORD) ② Mecc alte generator (mecc alte) ③ Marathon power generation Generators with excellent performance such as marathon.
3. The control system has high precision: the diesel generator set control system produced by our company uses the LCD screen controller,Such as: ① deep sea controller (DSE) ② smartgen controller (smartgen) has the characteristics of high integration and high management accuracy.
4. Years of industry experience, quality assurance,Years of industry experience, professional scientific research institutions
5. The company will provide you with all-round services with the service tenet of "customer first, service first".
6. Powerful manufacturers create gold medal quality.Diesel generator sets are widely used in high-rise office buildings, hotels, hospitals, industrial and mining, rural areas, field operations in mountainous areas, power and lighting for enterprises, institutions, schools or professional households.
7. Professional generator set application integration capability.Structural/functional solutions suitable for various application scenarios.
Gen-set Specifications | |||
Gen-set Model | HD-1000GF | Rated Frequency | 50Hz/60Hz |
Rated Power | 1000kWe/1250kVA | Rated Speed | 1500rpm/1800rpm |
Standby Power | 1100kWe/1375kVA | Rated Current | 1800A(400V) |
Rated Voltage | 400/440V | Weight | 8800kg |
Fuel Consumption(Rated) | 203g/kW•h | Outline Dimension(L×W×H) | 5000×2000×2500mm |
Engine Technical Datasheet | |||
Engine Model | 4012-46TWG2A | 3Brand | Perkins |
Rated Power | 1113kW | Number of Cylinders | 12 |
Bore×Stroke | 160mm×190mm | Governor | Electronic |
Displacement | 45.84Liters | Lubricant Capacity | 177L |
Starting method | DC24V |
Alternator Technical Datasheet | |||
Alternator Model | S6L1D-G41 | Brand | Stamford |
Rated Power | 1008kW | Protection Grade | IP23 |
Voltage regulation | AVR | Excitation | brushless PMG |
Insulation Grade | H | Type | 3phase 4wire |
Control system Technical Datasheet |
1,Multi-interface display unit work and alarm state, intuitively clear, LCD displays the parameters of diesel engines. 2,Microcomputer can be set on the control panel input, output, alarm, delay and other 3,parameters.Maintenance, manual, automatic and other modes of operation. 1,Engine Data: Speed, Oil Pressure, Water Temperature, Battery Volt, Running TimingAlternator 2,Data: Gen-set/Mains Frequency, Gen-set/Mains 3-Phase Volt(L-L,L-N) ,Current, kVA,kW,PF,kVAR,kWh,kVAh,kVARh 1,Over / under speed, Low Oil Pressure, High Water Temperature, under Battery Volt,Low water level,Three failed to start alarm 2,Over / under voltage,Over current,Over / under frequency, Over Power, Short circuit |